Background

The diagnostic investigation of sensitization to dust mites is performed through measurement of specific IgE and cutaneous immediate hypersensitivity tests. The general aim of this study was to comparatively evaluate the diagnostic accuracy of immediate hypersensitivity skin tests and specific IgE for Dermatophagoides pteronyssinus (Dp) and Blomia tropicalis in patients with allergic rhinitis.

Methods

A retrospective study evaluating patients between 5-65 years of age, of both sexes, with a clinical diagnosis of allergic rhinitis, was performed. The control group consisted of staff and students of the institution, aged 18-65 years, of both sexes, and no prior or current history of allergic rhinitis, asthma or atopic dermatitis. The measurement of specific IgE for Dp and Bt was performed using the ImmunoCAP and in the immediate hypersensitivity to Dp and Bt skin tests extracts from the FDA Allergenic were used.

Results

We evaluated 42 patients with allergic rhinitis and included 22 patients in the control group. We observed 90% sensitivity for Dp skin tests and 66.7% for measurement of specific IgE to Dp (p = 0.0001); 84% for Bt skin tests, and 61.9% for IgE specific for Bt (p = 0.0004). The specificity was 91% for Dp and Bt skin tests and 86% for specific Bt and Dp IgE (p> 0.05). The positive predictive value (PPV) was 95% for Dp skin tests, 94% for BT skin tests and 90% for serum specific IgE for both Dp and BT (p> 0.05). The negative predictive value (NPV) was 83% for Dp skin tests and 58% for the measurement of specific IgE for Dp (p = 0.0001); 77% for Bt skin tests and 54% for serum specific IgE for Bt (p = 0.001).

Conclusions

In the studied population, there was a higher sensitivity and better NPV of skin tests for Dp and Bt compared to the dosage of specific IgE. These results reinforce the usefulness of skin tests for immediate hypersensitivity to mites in clinical practice.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Rito, H.C., Rubini, N., Capelo, A.V. et al. Comparative evaluation of the accuracy of skin tests and measurement of mite-specific IgE in patients with allergic rhinitis. World Allergy Organ J 8 (Suppl 1), A146 (2015). https://doi.org/10.1186/1939-4551-8-S1-A146

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1186/1939-4551-8-S1-A146